Usage Methods and Precautions of Negative Pressure Autopsy Table

2025.02.06
In fields such as medical research and forensic identification, dissection work has extremely high requirements for environmental safety and operational standardization. As Guangzhou Cleanroom Construction Co., Ltd., which specializes in the production of purification equipment, the negative pressure autopsy tables we launch provide reliable guarantees for these tasks. Today, we will introduce in detail the usage methods and precautions of negative pressure autopsy tables.
0

I. The Important Role of Negative Pressure Autopsy Tables

A negative pressure autopsy table is a device specifically designed for dissection operations. Its core function is to use negative pressure technology to quickly collect, filter, and treat harmful gases, aerosols, and other pollutants generated during the dissection process, preventing their diffusion into the surrounding environment, thus effectively protecting the safety of operators and the surrounding environment. It plays a crucial role in handling samples of infectious diseases or other potentially hazardous samples and is a key device to ensure the safe progress of dissection work.

II. Detailed Explanation of Usage Methods

1. Preparation Work: Before using the negative pressure autopsy table, first check whether the various parameters of the device are normal, such as whether the negative pressure value is within the specified range and whether the ventilation system is operating well. At the same time, ensure that all the tools and equipment on the autopsy table are complete and in a usable state, such as dissection knives, lighting equipment, specimen collection containers, etc.
2. Starting the Equipment: Connect the power supply and start the negative pressure system and ventilation system of the negative pressure autopsy table. After the equipment runs stably and the negative pressure value reaches the set standard, the next operation can be carried out. This step is very crucial, and a stable negative pressure environment is the basis for ensuring that pollutants do not spread during the dissection process.
3. Placing the Sample: Carefully place the sample to be dissected on the autopsy table, and pay attention to avoiding unnecessary damage to the sample. At the same time, adjust the position of the sample to make it in a position convenient for operation.
4. Dissection Operation: The operator should perform the operation according to the standard dissection process. During the operation, pay attention to standard actions to avoid generating excessive aerosols. At the same time, always pay attention to the operating status of the negative pressure autopsy table to ensure that the equipment is working properly.
5. Cleaning and Shutting Down: After the dissection work is completed, promptly clean the residues on the autopsy table and disinfect the used tools. Then, first turn off the negative pressure system, then turn off the ventilation system, and finally cut off the power supply.

III. Precautions

1. Personal Protection: When using the negative pressure autopsy table, operators must wear professional protective equipment, including protective clothing, protective gloves, goggles, masks, etc., to ensure their own safety. At the same time, regular health checks should be carried out to promptly detect possible health risks.
2. Equipment Maintenance: Regularly maintain the negative pressure autopsy table, check whether all components of the equipment are working properly, such as whether the filter needs to be replaced and whether the ventilation ducts are blocked. Replace aging or damaged components in a timely manner to ensure that the equipment is always in good operating condition.
3. Emergency Handling: During use, if equipment failures or other emergencies occur, such as an abnormal drop in the negative pressure value, the operation should be stopped immediately and corresponding emergency measures should be taken. For example, quickly evacuate the site and notify professional maintenance personnel for repair.
4. Sample Management: Manage the dissection samples strictly in accordance with relevant regulations to ensure that the collection, transportation, storage, and processing processes of the samples meet biosafety requirements. Avoid sample leakage or cross - contamination to ensure the safety of the entire dissection work.
The correct use and maintenance of negative pressure autopsy tables are crucial for ensuring the safe and efficient progress of dissection work. Guangzhou Cleanroom Construction Co., Ltd. will always adhere to the concepts of professionalism and innovation, continuously improve product quality and service levels, and provide better equipment and solutions for fields such as medical research and forensic identification. If you have any questions or needs about negative pressure autopsy tables or other purification equipment, please feel free to contact us.