In laboratories, electronics workshops and other places, horizontal flow workbenches are important equipment to ensure a clean and safe working environment. However, like any mechanical equipment, horizontal flow workbenches may also experience some failures during use. Don't worry. Today, we will bring you a quick troubleshooting guide for daily failures of horizontal flow workbenches.
I. Unstable airflow
Symptom: The airflow speed of the horizontal flow workbench is unstable, either speeding up or slowing down, or there is a deviation in the airflow direction.
Solution:
- Check the fan: First, check whether the fan is operating normally and whether there is abnormal noise or vibration. If the fan malfunctions, contact professional personnel for repair or replacement in time.
- Clean the filter: A clogged filter may cause unstable airflow. Clean or replace the filter regularly to ensure smooth air circulation.
- Check the air duct: Check whether the air duct is clogged or leaking. If a problem is found, clean or repair the air duct in time.
II. Excessive noise
Symptom: The horizontal flow workbench generates relatively loud noise during operation.
Solution:
- Check the fan: Fan aging or damage may lead to excessive noise. Check the operation of the fan. If there is a problem, replace the fan in time.
- Tighten components: Check whether all components of the horizontal flow workbench are tightened. If there is any looseness, tighten it in time.
- Check the shock absorption device: If the horizontal flow workbench is equipped with a shock absorption device, check whether the shock absorption device is working properly. If there is a problem, replace or repair the shock absorption device in time.
III. Lighting failure
Symptom: The lighting system of the horizontal flow workbench is not on or flickering.
Solution:
- Check the bulb: First, check whether the bulb is damaged. If the bulb is damaged, replace the bulb in time.
- Check the circuit: Check whether the circuit of the lighting system is normal. If there is a problem, contact professional personnel for repair in time.
IV. Operation panel failure
Symptom: The operation panel of the horizontal flow workbench cannot be operated normally or shows abnormal display.
Solution:
- Check the power supply: Check whether the power supply of the operation panel is normal. If there is a power failure, repair or replace the power supply in time.
- Restart the equipment: Try restarting the horizontal flow workbench to see if it can solve the operation panel failure. If the problem still exists, contact professional personnel for repair in time.
In conclusion, various failures may occur in the horizontal flow workbench during use. But as long as we master the correct solutions, we can quickly solve these problems and ensure the normal operation of the horizontal flow workbench. At the same time, in order to reduce the occurrence of failures, we should also perform regular maintenance and upkeep on the horizontal flow workbench to extend its service life.