Proper maintenance and care of an air shower are essential for its efficiency and longevity. Follow these guidelines to ensure optimal performance:
Maintenance Guidelines:
1. Installation and Positioning:
The installation and positioning of the air shower should not be arbitrarily moved for rectification. If there is a need to change the displacement, guidance from the installation personnel and manufacturer must be sought. The displacement must be recalibrated to the ground level to prevent deformation of the door frame and affect the normal operation of the air shower.
2. Environment:
The equipment and environment of the air shower room should be well-ventilated and dry.
3. Control Switches:
Do not touch or use all control switches in the normal working state of the air shower.
4. Sensing Area:
In the human or cargo sensing area, the switch can only enter the shower program after receiving the sensing.
5. Transporting Items:
Do not transport large items from the air shower room to avoid damaging the surface and electrical controls.
6. Panels:
Air drenched indoor and outdoor panels, do not touch with hard objects to avoid scratching.
7. Doors:
The air shower room door is electronic interlocked, and when one door is opened, the other door automatically locks. Do not force the opening and closing of both doors at the same time, and do not force the opening and closing of either door when the switch is in operation.
8. Rinsing Time:
Once the rinsing time is set, do not adjust it arbitrarily.
9. Management:
The air shower room needs to be managed by a responsible person, and the primary filter should be replaced regularly every quarter.
10. HEPA Filter:
Replace the HEPA filter in the air shower every year on average.
11. Door Handling:
The air shower room uses light opening and light closing of the indoor and outdoor doors of the air shower.
12. Malfunctions:
When a malfunction occurs in the air shower room, it should be reported to the maintenance personnel for repair in a timely manner. Generally, it is not allowed to activate the manual button.
Air Shower Upkeep Guidelines:
1. Professional Operation:
The maintenance and repair equipment of the air shower room shall be operated by professionally trained personnel.
2. Circuit Maintenance:
The circuit of the air shower room is installed in the box above the entrance door. Open the panel door lock to repair and replace the circuit board. When repairing, be sure to turn off the power supply.
3. HEPA Filter Replacement:
The HEPA filter is installed in the middle section of the main box (behind the nozzle plate), and can be removed by disassembling the nozzle panel.
4. Door Closer Installation:
When installing the door closer body, the speed control valve faces the door hinge, and when closing the door, let the door close freely under the action of the door closer. Do not add external force, otherwise the door closer may be damaged.
5. Fan Maintenance:
The fan of the air shower room is installed below the side of the air shower box, and the return air filter is disassembled.
6. Magnetic Switch and Electronic Latch:
The door magnetic switch and electronic latch (double door interlock) are installed properly to ensure security and functionality.